- Thermal endurance up to 85 °C /120 °C. - Splash-proof to IP 66. - Adjustment via Z7684 test light. - The mould can only be closed when the ejector system has reached its limit position. - Fine adjustment and locking with Z7608. - Sturdy aluminium housing with integral micro- limit switch. - Cast housing protected against short-circuits. - Connection to the machine control system via Z7602 / Z7603. - Connection housing Z7624 must be used if several limit switches have to be switched simultaneously. - Dummy plug Z7626 must be fitted on unused connections. ATTENTION! Safe only for driving voltage up to max. 30 V, 2 A / 24 V, 2 A.